Each transmitter (emkaPACK) simultaneously can transmit the follownig signals:
> view examples of acquired data | top of page |
The telemetry system can be used to acquire biological data from large subjects such as dogs, primates, pigs and minipigs.
emkaTECHNOLOGIES can supply custom-made clothing for different species:
| top of page |
As part of a telemetry set-up, the emkaPACK transmitter may be used for acquiring:
| top of page |
Each type of bioelectric potential has a characteristic amplitude, frequency, signal-noise ratio, etc. and requires specially designed components. Currently, the emkaPACK telemetry system is designed to measure ecg only. However please let us know if you are interested in measuring other biopotentials. Our aim is to satisfy our customers' requirements.
| top of page |
We developed the nibp module to meet the demand for a reliable noninvasive system for measuring blood pressure in unrestrained large animals.
Researchers are aware of some of the inherent limitations of noninvasive measurement but realise the value of obtaining blood pressure data during long-term external telemetry recording sessions. emka TECHNOLOGIES is the first company to offer the ability to measure blood pressure completely noninvasively in freely moving animals.
As of mid-March 2009, the nibp module from emka TECHNOLOGIES was undergoing testing by a CRO. Preliminary results based on 1000 hours of data from 40 dogs indicate that from 60% to 90% of inflation cycles produce reliable data.
The system has the following features:
| top of page |
The use of a pressure sensor (t-PRESS unit) in combination with a vascular access port (VAP) is today a feasible alternative and in many cases advantageous to use of implants alone:
In short, VAP pressure measurements are accurate, reliable, and extremely cost-effective. Furthermore, the technique is associated with minimal histopathological changes in animals implanted for up to a year (Bartoli et al., 2007 - abstract).
| top of page |
Yes!
emkaBELT is the emkaPACK module for customers who want to acquire lung volume in a noninvasive manner from large subjects such as dogs, primates and pigs. It is based on respiratory inductive plethysmography (RIP), a proven technology for quantitative and qualitative measurements.
> see the emkaBELT | top of page |
Less than 5 minutes!
Clothing has been manufactured according to our specifications, and both the emkaPACK transmitter and emkaBELT respiration belts are easy to apply and comfortable for subjects. The emkaPACK and external emkaBELT devices fit snugly inside the jacket pockets.
> see equiped dog subject| top of page |
Yes!
The emkaPACK transmitter runs on two AA/R6 alkaline batteries, which allow for continuous acquisition for an average of 80 hours (with acquisition of 7-lead ecg and activity).
Of course, the runtime is reduced if the transmission power of the emkaPACK has to be increased or if you use modules for the acquisition of other types of signals (noninvasive blood pressure, noninvasive lung volume...)
| top of page |
Yes, but it is recommended to use single-use batteries to reduce the risk and the duration of recording gaps during experimental sessions. This is because:
| top of page |
One of the connectors on the emkaPACK can receive a signal from any strain-gauge transducer in the range 0-3V.
| top of page |
The telemetry-over-Ethernet (ToE) systems can be used in 32-200 subjects simultaneously because the same frequencies are reused. A frequency manager ensures that transmitter/receiver pairs using the same frequency are sufficiently distant from each other. Furthermore, the manager can modify the frequency of a transmitter/receiver pair during an experiment, to optimise the signal quality without interrupting acquisition.
| top of page |
Calibration, an essential operation for any data acquisition system, must be done to allow the system to convert the voltage at one end of the data acquisition chain (from the transducer) into the actual quantity at the other end of the chain (displayed onscreen by the acquisition software). Calibration involves application of a quantity (voltage, pressure, force etc.) of known value.
The calibration of all electronic components and systems needs to be verified regularly to account for voltage 'drift' that occurs due to wear and tear of components, operating environment and storage conditions, etc.
| top of page |
The telemetry system is calibrated at installation, and must be verified annually thereafter. You may also perform calibration more often if necessary. As for each type of signal, calibration should be performed as often as necessary.
In other words, there are no general rules - the frequency of calibration is imposed by internal regulations or is indicated in certain situations, e.g. exposure to highly variable temperature, humidity, shock etc.
The exceptions are the activity and temperature options which are factory calibrated. They are both designed to provide a constant signal over time.
| top of page |
In most systems, any data acquisition software can be used though we recommend the use of iox2.
| top of page |
Yes !
Data acquisition software by emka TECHNOLOGIES can acquire signals from the video camera.
> see synchronized video ecg recordings| top of page |
Yes !
emka TECHNOLOGIES is committed to the continued production of open data acquisition and analysis systems. An open system allows software and hardware from multiple manufacturers to be used together, in any combination that suits the investigator's needs. Open systems can lower cost sand offer enhanced features not available in closed, proprietary systems.
| top of page |
Yes!
Most of our customers use ecgAUTO to process data files recorded using iox2 (data acquisition software).
However we can also provide data conversion tools for customers who use other data acquisition systems, specifically:
For customers running a DSI™ telemetry system with DSI™ OpenArt™ software v2.3 or higher: emka TECHNOLOGIES has developed a direct data link: a single PC runs OpenArt™ and iox2 simultaneously so that data flow seamlessly in real-time from the implants to iox.
| top of page |
glp compliance facilitates the conduct of studies, promotes their full and accurate reporting, and guarantees data integrity.
All emka TECHNOLOGIES software are 100% compatible with glp requirements for strict toxicology, safety pharmacology, and general pharmacology applications. They also provide you with an easy and reliable solution for a 21 cfr part 11-compliant environment.
All our telemetry systems have also been designed with glp- and 21 cfr part 11-compliance in mind.
Software features include:
> learn about our validation services
> download our validation services brochures
emka TECHNOLOGIES features on the list of vendors of 21 cfr part 11-compliant solutions of > www.21cfrpart11.com
| top of page |
Yes, it is possible to change ecg configuration. However, the system must be adapted by using appropriate cable and reconfiguring emkaPACK transmitter internal software (this is done by emka TECHNOLOGIES).
Correct cable and reconfiguration are particularly important if you decide to 'down-grade' ecg configuration (e.g. 7-lead to 6-lead, or 6-lead to 1-lead). If the appropriate cable is not used, unused electrodes may cause interference. To ensure accurate signals, every wire of the ecg cable must be connected to the subject, regardless of whether its signal will be acquired.
| top of page |
emka non-invasive telemetry brochure
> download document
3.3 MB
emka iox2 acquisition and analysis software brochure
> download document
1.4 MB
ecgAUTO ecg & cardiovascular analysis software - multi-species, multi-lead
> download document
1.94 MB
emka telemetry integrated systems brochure
> download document
2.6 MB
emkaPACK brochure
> download document
1.3 MB
emkaPACK options brochure
> download document
4.7 MB
emkaBELT brochure
> download document
4.5 MB
APPT access port pressure telemetry brochure
> download document
3.2 MB
OPT oscillometric pressure non-invasive telemetry brochure
> download document
4.4 MB
emka TECHNOLOGIES' solutions for primates brochure
> download document
3.8 MB
emka TECHNOLOGIES' telemetry in swine brochure
> download document
4.3 MB
emka TECHNOLOGIES' rodentPACK telemetry for rodents brochure
> download document
3.9 MB
emka TECHNOLOGIES eeg studies brochure
> download document
2.1 MB
non-invasive telemetry and ecgAUTO brochure
> download document
2.4 MB
非侵襲性テレメトリーシステム
non-invasive telemetry brochure in Japanese
> download document
3.6 MB
动物无创生理信号遥测统系
non-invasive telemetry brochure in Chinese
> download document
6.4 MB
studyDESIGNER software for organizing toxicology and safety pharmacology studies
> download document
2.18 MB
glpMODULES
> download document
1.98 MB
regulatory compliance & validation services
> download document
1.75 MB
adapting telemetry setups to large populations
ALN Magazine - october 2007
> download document
36 KB
software for the wireless age
ALN Europe - march 2008
> download document
48 KB